{"id":548,"date":"2020-08-10T18:12:57","date_gmt":"2020-08-10T18:12:57","guid":{"rendered":"https:\/\/incendio.pt\/manual-seguranca\/?p=548"},"modified":"2026-01-24T20:01:09","modified_gmt":"2026-01-24T20:01:09","slug":"sadi-geral","status":"publish","type":"post","link":"https:\/\/incendio.pt\/mse\/sadi-geral\/","title":{"rendered":"DETE\u00c7\u00c3O DE INC\u00caNDIO &#8211; Requisitos Gerais"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\"><mark style=\"background-color:#f0f0f0\" class=\"has-inline-color\">RT-SCIE Artigos 116\u00ba a 132\u00ba<\/mark><\/h4>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">Os edif\u00edcios devem ser equipados com instala\u00e7\u00f5es que permitam detetar o inc\u00eandio o mais precocemente poss\u00edvel e, em caso de emerg\u00eancia, difundir o alarme para os seus ocupantes, alertar os bombeiros e acionar sistemas e equipamentos de seguran\u00e7a.<\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">Est\u00e3o isentos de obrigatoriedade de instala\u00e7\u00e3o de alarme os recintos ao ar livre e os itinerantes ou provis\u00f3rios e os que estejam protegidos totalmente por sistema fixo de extin\u00e7\u00e3o autom\u00e1tica de inc\u00eandios por \u00e1gua*. (e as habita\u00e7\u00f5es)<\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">Nos edif\u00edcios onde n\u00e3o existam meios humanos para verificar alarmes restritos (aviso sonoro apenas na central e repetidores) a atua\u00e7\u00e3o de um dispositivo de dete\u00e7\u00e3o autom\u00e1tica deve acionar de imediato o alarme geral. No caso de existirem meios humanos, deve existir uma temporiza\u00e7\u00e3o entre o alarme restrito e alarme geral nos caso de dete\u00e7\u00e3o autom\u00e1tica.<\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">Os sistemas podem ser do tipo <strong>cableado ou sinal radioel\u00e9trico<\/strong>, desde que cumpram a norma  <strong>EN54<\/strong>. (art. 117\u00ba)<\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\"><em>\u00c9 obrigat\u00f3ria manuten\u00e7\u00e3o do equipamento, efetuada por empresa certificada.<\/em> (RJ-SCIE art. 25\u00ba). O n\u00e3o cumprimento poder\u00e1 ser pun\u00edvel com coimas entre 370\u20ac e 44.000\u20ac dependendo da gravidade<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\">SISTEMAS DE DETE\u00c7\u00c3O DE INC\u00caNDIO<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Um sistema de dete\u00e7\u00e3o de inc\u00eandio comum poder\u00e1 ser do tipo convencional (por zonas de dete\u00e7\u00e3o) ou do tipo anal\u00f3gico endere\u00e7\u00e1vel (por endere\u00e7o do dispositivo). <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Os <strong>sistemas convencionais<\/strong> apenas conseguem &#8220;ver&#8221; as zonas e n\u00e3o os seus componentes. Ideal para espa\u00e7os pequenos pelo seu baixo pre\u00e7o. O princ\u00edpio de funcionamento \u00e9 em estrela, ou seja, por cada zona parte um cabo da central que liga cada um dos detetores. No final \u00e9 colocado um fim de linha (resist\u00eancia ou condensador).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Os <strong>sistemas endere\u00e7\u00e1veis<\/strong> j\u00e1 conseguem distinguir todos os seus perif\u00e9ricos, sendo mais dispendioso, mas torna-se ideal para grandes instala\u00e7\u00f5es, devido \u00e0 sua r\u00e1pida identifica\u00e7\u00e3o do local em alarme, funcionalidades acrescidas de manuten\u00e7\u00e3o e robustez do equipamento central e perif\u00e9rico. \u00c9 tamb\u00e9m mais fi\u00e1vel, j\u00e1 que a sua estrutura em anel liga os equipamentos pela entrada e pela sa\u00edda, ou seja, mesmo se existir um corte no cabo, num determinado ponto, ainda continua a existir comunica\u00e7\u00e3o \u00e0 central pelo outro lado.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"358\" src=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-large.png\" alt=\"sistema de dete\u00e7\u00e3o de inc\u00eandio endere\u00e7avel vs sistema convencional\" class=\"wp-image-1727\" srcset=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-large.png 1024w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-medium.png 600w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-768x269.png 768w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-1536x538.png 1536w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-2048x717.png 2048w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-150x52.png 150w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-300x105.png 300w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-696x244.png 696w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-1068x374.png 1068w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sistema-analogico-convencional-1920x672.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>CENTRAL DE INC\u00caNDIO<\/strong> (Central de Sinaliza\u00e7\u00e3o e Comando) &#8211; Equipamento central que comunica com os restantes equipamentos de entrada e sa\u00edda.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>EQUIPAMENTO DE DETE\u00c7\u00c3O<\/strong>: Dispositivos que detetam automaticamente um poss\u00edvel inc\u00eandio. <\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>EQUIPAMENTO DE A\u00c7\u00c3O MANUAL: <\/strong>Bot\u00f5es de acionamento de alarme ou de corte manual<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>EQUIPAMENTO DE ALARME<\/strong>: Dispositivos sonoros e visuais, como sirenes e sinalizadores e transmissores autom\u00e1ticos com mensagem de alerta.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>EQUIPAMENTO DE ENTRADA E SA\u00cdDA<\/strong>: M\u00f3dulos com ordens de comando de sa\u00edda para outros equipamentos como elevadores, desenfumagem, etc. M\u00f3dulos para a rece\u00e7\u00e3o de sinais de outras centrais e outros equipamentos de dete\u00e7\u00e3o e controlo.<\/li>\n\n\n\n<li><strong>EQUIPAMENTO REPETIDOR: <\/strong>Equipamento semelhante \u00e0 central de inc\u00eandio que repete as informa\u00e7\u00f5es de avaria e alarme de inc\u00eandio <\/li>\n\n\n\n<li><strong>MODULO DE COMUNICA\u00c7\u00c3O<\/strong>: Modulo que envia a comunica\u00e7\u00e3o de avaria\/alarme via linha telef\u00f3nica fixa, m\u00f3vel ou Ethernet<\/li>\n\n\n\n<li><strong>BATERIAS DE BACKUP<\/strong>: Baterias a incluir na central para assegurar o funcionamento de todo o sistema mesmo no caso de quebra de energia el\u00e9trica.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>RT-SCIE Artigos 116\u00ba a 132\u00ba Os edif\u00edcios devem ser equipados com instala\u00e7\u00f5es que permitam detetar o inc\u00eandio o mais precocemente poss\u00edvel e, em caso de emerg\u00eancia, difundir o alarme para os seus ocupantes, alertar os bombeiros e acionar sistemas e equipamentos de seguran\u00e7a. Est\u00e3o isentos de obrigatoriedade de instala\u00e7\u00e3o de alarme os recintos ao ar [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2361,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[83],"class_list":["post-548","post","type-post","status-publish","format-standard","has-post-thumbnail","category-detecao-de-incendios","tag-rt-scie"],"image_feature":"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/detecao-incendio.png","author_name":"Gon\u00e7alo Villa de Brito","_links":{"self":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/548","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/comments?post=548"}],"version-history":[{"count":26,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/548\/revisions"}],"predecessor-version":[{"id":2365,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/548\/revisions\/2365"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/media\/2361"}],"wp:attachment":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/media?parent=548"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/categories?post=548"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/tags?post=548"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}