{"id":283,"date":"2020-07-31T14:20:31","date_gmt":"2020-07-31T14:20:31","guid":{"rendered":"https:\/\/incendio.pt\/manual-seguranca\/?p=93"},"modified":"2026-01-24T19:59:45","modified_gmt":"2026-01-24T19:59:45","slug":"sinalizacao-rt-scie-111o","status":"publish","type":"post","link":"https:\/\/incendio.pt\/mse\/sinalizacao-rt-scie-111o\/","title":{"rendered":"SINALIZA\u00c7\u00c3O"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\"><mark style=\"background-color:#f0f0f0\" class=\"has-inline-color\">RT-SCIE Artigo 108\u00ba<\/mark><\/h4>\n\n\n\n<p>Todos os edif\u00edcios devem possuir placas de sinaliza\u00e7\u00e3o de emerg\u00eancia adequada que indiquem respetivamente <strong>proibi\u00e7\u00e3o, perigo, emerg\u00eancia, meios de interven\u00e7\u00e3o<\/strong> <strong>e informa\u00e7\u00e3o<\/strong> consoante o seu formato e cor, devendo os mesmos serem em material r\u00edgido fotoluminescente.<\/p>\n\n\n\n<p><strong>COM QUE SIMBOLOGIA?<\/strong><\/p>\n\n\n\n<p>\u00c9 poss\u00edvel a utiliza\u00e7\u00e3o da simbologia da Portaria n\u00ba 1456-A\/95&nbsp;&nbsp; <strong>ou<\/strong><strong>&nbsp; <\/strong>&nbsp;da mais recente NP EN ISO 7010<\/p>\n\n\n\n<p>N\u00e3o \u00e9 permitida a sinaliza\u00e7\u00e3o com texto apenas do tipo \u201cSA\u00cdDA\u201d ou \u201cEXIT\u201d<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/NP-EN-ISO-7010-1-large.png\" alt=\"\" class=\"wp-image-1637\" width=\"580\" height=\"279\"\/><\/figure>\n<\/div>\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/Portaria-1456-A-95-1-large.png\" alt=\"\" class=\"wp-image-1639\" width=\"583\" height=\"272\"\/><\/figure>\n<\/div>\n\n\n<p><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><mark style=\"background-color:#f0f0f0\" class=\"has-inline-color\">RT-SCIE Artigo 109\u00ba<\/mark><\/h4>\n\n\n\n<p><strong>COM QUE TAMANHO?<\/strong><\/p>\n\n\n\n<p>As placas devem ter \u00e1rea (A) n\u00e3o inferior \u00e0s determinadas em fun\u00e7\u00e3o da&nbsp; dist\u00e2ncia (d) a que devem ser vistas, com um m\u00ednimo de 6m e um m\u00e1ximo de 50m.&nbsp; Exemplo: Para uma dist\u00e2ncia de 10m devemos ter A=10\u00b2\/2000 = 5m\u00b2. De salientar que a \u00e1rea \u00e9 apenas do pictograma excluindo a cercadura. <em>Para c\u00e1lculo da \u00e1rea m\u00ednima afeta a cada pictograma <\/em><em>deve considerar-se <\/em><em>o lado menor do sinal de acordo com a <\/em><em>norma ISO <\/em><em>3864:1984<\/em><em>. Sendo A= (\u00c1rea menor)<\/em> \u00b2<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sinal-distancia-large.png\" alt=\"\" class=\"wp-image-1645\" width=\"551\" height=\"270\"\/><\/figure>\n<\/div>\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sinal-visao-large.png\" alt=\"\" class=\"wp-image-1647\" width=\"538\" height=\"310\"\/><\/figure>\n<\/div>\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-table aligncenter is-style-stripes\"><table class=\"has-background\" style=\"background-color:#e7f5fe\"><tbody><tr><td><strong>Dist\u00e2ncias de visualiza\u00e7\u00e3o<\/strong><\/td><td><strong>6 m <\/strong><\/td><td><strong>8 m<\/strong><\/td><td><strong>17 m<\/strong><\/td><td><strong>26 m<\/strong><\/td><td><strong>35 m<\/strong><\/td><\/tr><tr><td>\u00c1rea (cm2)<\/td><td>180<\/td><td>320<\/td><td>1445<\/td><td>3380<\/td><td>6125<\/td><\/tr><tr><td>Placa quadrada  (<strong>mm<\/strong>)<\/td><td>150x 150<\/td><td>200x 200<\/td><td>400x 400<\/td><td>600x<br>600<\/td><td>800x 800<\/td><\/tr><tr><td>Placa Retangular 1:2 (<strong>mm<\/strong>)<\/td><td>100x 200<\/td><td>150x 300<\/td><td>300x 600<\/td><td>500x  1000<\/td><td>600x <br>1200<\/td><\/tr><tr><td>Placa Retangular 2:3 (<strong>mm<\/strong>)<\/td><td>150x 200<\/td><td>200x 300<\/td><td>400x 600<\/td><td>500x <br>750<\/td><td>700x <br>1050<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Exemplo de dist\u00e2ncias<\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><mark style=\"background-color:#f0f0f0\" class=\"has-inline-color\">RT-SCIE Artigo 111\u00ba<\/mark><\/h4>\n\n\n\n<p><strong>COM QUE FORMATO?<\/strong><\/p>\n\n\n\n<p>Existem basicamente 3 tipos de formatos:<\/p>\n\n\n\n<p>\u2022Sinal de uma face (leitura de 90\u00ba em frente, paralela \u00e1 parede)<\/p>\n\n\n\n<p>\u2022Sinal de dupla face (leitura de 90\u00ba em ambos os lados, perpendicular \u00e1 parede)<\/p>\n\n\n\n<p>\u2022Sinal Panor\u00e2mico (leitura a 180\u00ba, em duas faces a 45\u00ba cada)<\/p>\n\n\n\n<p>As placas devem ter um tamanho igual \u00e1 dist\u00e2ncia\u00b2\/2000, com dist\u00e2ncia m\u00ednima de 6 m e m\u00e1xima de 50 m, como mostram os exemplos do quadro seguinte:<\/p>\n\n\n\n<p><em>As placas t\u00eam <\/em><em>obrigatoriamente <\/em><em>de <\/em><em>indicar, na parte inferior direita, a <\/em><em>marca ou nome do fabricante e os valores de luminesc\u00eancia<\/em><em>.<\/em><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"192\" src=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-10-medium.png\" alt=\"\" class=\"wp-image-1505\" srcset=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-10-medium.png 600w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-10-768x246.png 768w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-10-150x48.png 150w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-10-300x96.png 300w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-10-696x223.png 696w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-10.png 901w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<p><\/p>\n\n\n\n<p><strong>A QUE ALTURA?<\/strong><\/p>\n\n\n\n<p>As placas de sa\u00edda de emerg\u00eancia, sinaliza\u00e7\u00e3o de equipamentos de 1\u00aa interven\u00e7\u00e3o e botoneiras manuais de emerg\u00eancia devem ser instaladas a uma altura entre <strong>2,1m e 3m. <\/strong>As placas com informa\u00e7\u00e3o adicional e instru\u00e7\u00f5es devem ser instaladas entre <strong>1,2m e 1,8m <\/strong>(instru\u00e7\u00f5es de extintores e carreteis, porta corta-fogo, barra antip\u00e2nico, etc).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"429\" height=\"335\" src=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-8-large.png\" alt=\"\" class=\"wp-image-1502\" srcset=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-8.png 429w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-8-150x117.png 150w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-8-300x234.png 300w\" sizes=\"auto, (max-width: 429px) 100vw, 429px\" \/><\/figure>\n<\/div>\n\n\n<p><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><mark style=\"background-color:#f0f0f0\" class=\"has-inline-color\">RJ-SCIE Artigo 23\u00ba e Despacho 686\/2023<\/mark><\/h4>\n\n\n\n<p><strong>QUEM PODE INSTALAR E MANTER O SISTEMA?<\/strong><\/p>\n\n\n\n<p>A instala\u00e7\u00e3o de sinaliza\u00e7\u00e3o de emerg\u00eancia dever\u00e1 ser instalado por um t\u00e9cnico respons\u00e1vel inscrito na ANEPC com a especializa\u00e7\u00e3o de (h) sinaliza\u00e7\u00e3o de seguran\u00e7a.<\/p>\n\n\n\n<p>Relativamente \u00e1 manuten\u00e7\u00e3o, o equipamento dever\u00e1 ser verificado no m\u00ednimo, anualmente por t\u00e9cnico respons\u00e1vel com inscri\u00e7\u00e3o na ANEPC.<\/p>\n\n\n\n<figure class=\"wp-block-image size-medium is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"40\" src=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-9-medium.png\" alt=\"\" class=\"wp-image-1503\" srcset=\"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-9-medium.png 600w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-9-768x52.png 768w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-9-150x10.png 150w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-9-300x20.png 300w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-9-696x47.png 696w, https:\/\/incendio.pt\/mse\/wp-content\/uploads\/image-9.png 964w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>RT-SCIE Artigo 108\u00ba Todos os edif\u00edcios devem possuir placas de sinaliza\u00e7\u00e3o de emerg\u00eancia adequada que indiquem respetivamente proibi\u00e7\u00e3o, perigo, emerg\u00eancia, meios de interven\u00e7\u00e3o e informa\u00e7\u00e3o consoante o seu formato e cor, devendo os mesmos serem em material r\u00edgido fotoluminescente. COM QUE SIMBOLOGIA? \u00c9 poss\u00edvel a utiliza\u00e7\u00e3o da simbologia da Portaria n\u00ba 1456-A\/95&nbsp;&nbsp; ou&nbsp; &nbsp;da mais [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2360,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[37],"tags":[83],"class_list":{"0":"post-283","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-sinalizacao-e-iluminacao","8":"tag-rt-scie"},"image_feature":"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/sinalizacao.png","author_name":"Gon\u00e7alo Villa de Brito","_links":{"self":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/283","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/comments?post=283"}],"version-history":[{"count":13,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/283\/revisions"}],"predecessor-version":[{"id":1651,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/283\/revisions\/1651"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/media\/2360"}],"wp:attachment":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/media?parent=283"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/categories?post=283"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/tags?post=283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}