{"id":1102,"date":"2022-06-05T23:10:17","date_gmt":"2022-06-05T23:10:17","guid":{"rendered":"https:\/\/incendio.pt\/mse\/?p=1102"},"modified":"2026-02-08T18:05:59","modified_gmt":"2026-02-08T18:05:59","slug":"cofres","status":"publish","type":"post","link":"https:\/\/incendio.pt\/mse\/cofres\/","title":{"rendered":"COFRES"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\"><strong>Normas t\u00e9cnicas aplic\u00e1veis<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Norma<\/strong><\/th><th><strong>Designa\u00e7\u00e3o<\/strong><\/th><th><strong>Aplica\u00e7\u00e3o<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>EN 1143-1<\/strong><\/td><td>Secure storage units \u2013 Requirements<\/td><td>Norma principal para cofres de alta seguran\u00e7a<\/td><\/tr><tr><td><strong>EN 1143-2<\/strong><\/td><td>Deposit systems<\/td><td>Cofres com dep\u00f3sito<\/td><\/tr><tr><td><strong>EN 14450<\/strong><\/td><td>Secure cabinets<\/td><td>Cofres de seguran\u00e7a interm\u00e9dia<\/td><\/tr><tr><td><strong>EN 15659<\/strong><\/td><td>Secure strong room doors<\/td><td>Portas de salas-forte<\/td><\/tr><tr><td><strong>EN 1047-1<\/strong><\/td><td>Fire resistance data cabinets<\/td><td>Prote\u00e7\u00e3o contra fogo<\/td><\/tr><tr><td><strong>EN 1300<\/strong><\/td><td>Secure storage units \u2013 Locks<\/td><td>Fechaduras certificadas<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Classes de resist\u00eancia (EN 1143-1)<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Classes <strong>0 a XIII<\/strong><\/li>\n\n\n\n<li>Cada classe corresponde a um <strong>valor m\u00e1ximo segur\u00e1vel<\/strong><\/li>\n\n\n\n<li>A classe exigida depende do:\n<ul class=\"wp-block-list\">\n<li>Tipo de atividade<\/li>\n\n\n\n<li>Valor armazenado<\/li>\n\n\n\n<li>Exig\u00eancia da seguradora \/ PSP<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Atividade vs Classe m\u00ednima de Cofre (EN 1143-1)<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Atividade \/ Estabelecimento<\/strong><\/th><th><strong>Classe m\u00ednima de cofre (EN 1143-1)<\/strong><\/th><th><strong>Observa\u00e7\u00f5es t\u00e9cnicas<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Ourivesaria \/ Relojoaria<\/td><td><strong>Classe I ou II<\/strong><\/td><td>Normalmente exigido cofre certificado e ancorado. Integra\u00e7\u00e3o com alarme recomendada.<\/td><\/tr><tr><td>Ourivesaria de elevado valor<\/td><td><strong>Classe III ou superior<\/strong><\/td><td>Exigido para valores elevados em stock. Frequentemente com atraso temporal.<\/td><\/tr><tr><td>Casa de penhores<\/td><td><strong>Classe II ou III<\/strong><\/td><td>Dependente do valor m\u00e1ximo armazenado.<\/td><\/tr><tr><td>Loja de compra e venda de ouro<\/td><td><strong>Classe II<\/strong><\/td><td>Cofre obrigat\u00f3rio para armazenamento fora do hor\u00e1rio.<\/td><\/tr><tr><td>Banco \/ Institui\u00e7\u00e3o financeira<\/td><td><strong>Classe V a X<\/strong><\/td><td>Normalmente salas-forte ou cofres de alta seguran\u00e7a.<\/td><\/tr><tr><td>Casino \/ Sala de jogo<\/td><td><strong>Classe IV ou superior<\/strong><\/td><td>Requisitos definidos pelo regulador e seguradora.<\/td><\/tr><tr><td>Farm\u00e1cia (estupefacientes)<\/td><td><strong>Classe I<\/strong><\/td><td>Pode ser exigido compartimento espec\u00edfico.<\/td><\/tr><tr><td>Posto de combust\u00edvel (numer\u00e1rio)<\/td><td><strong>Classe I<\/strong><\/td><td>Geralmente cofre com dep\u00f3sito e atraso temporal.<\/td><\/tr><tr><td>Supermercado \/ Retalho (numer\u00e1rio)<\/td><td><strong>Classe 0 ou I<\/strong><\/td><td>Cofres de dep\u00f3sito s\u00e3o comuns.<\/td><\/tr><tr><td>Hotel (valores de clientes)<\/td><td><strong>Classe 0 ou I<\/strong><\/td><td>Cofres de quarto seguem EN 14450.<\/td><\/tr><tr><td>Escrit\u00f3rios \/ empresas<\/td><td><strong>Classe 0<\/strong><\/td><td>Dependente do valor segurado.<\/td><\/tr><tr><td>Resid\u00eancia particular<\/td><td><strong>Classe 0 ou I<\/strong><\/td><td>Aceita\u00e7\u00e3o depende da seguradora.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Correspond\u00eancia t\u00edpica Classe EN vs Valor segur\u00e1vel<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><em>(valores indicativos, variam por seguradora)<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Classe EN 1143-1<\/strong><\/th><th><strong>Valor segur\u00e1vel t\u00edpico (\u20ac)<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Classe 0<\/td><td>at\u00e9 ~40.000 \u20ac<\/td><\/tr><tr><td>Classe I<\/td><td>at\u00e9 ~65.000 \u20ac<\/td><\/tr><tr><td>Classe II<\/td><td>at\u00e9 ~100.000 \u20ac<\/td><\/tr><tr><td>Classe III<\/td><td>at\u00e9 ~200.000 \u20ac<\/td><\/tr><tr><td>Classe IV<\/td><td>at\u00e9 ~400.000 \u20ac<\/td><\/tr><tr><td>Classe V<\/td><td>at\u00e9 ~800.000 \u20ac<\/td><\/tr><tr><td>Classe VI+<\/td><td>&gt; 1.000.000 \u20ac<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Normas t\u00e9cnicas aplic\u00e1veis Norma Designa\u00e7\u00e3o Aplica\u00e7\u00e3o EN 1143-1 Secure storage units \u2013 Requirements Norma principal para cofres de alta seguran\u00e7a EN 1143-2 Deposit systems Cofres com dep\u00f3sito EN 14450 Secure cabinets Cofres de seguran\u00e7a interm\u00e9dia EN 15659 Secure strong room doors Portas de salas-forte EN 1047-1 Fire resistance data cabinets Prote\u00e7\u00e3o contra fogo EN 1300 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2428,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[107],"tags":[],"class_list":["post-1102","post","type-post","status-publish","format-standard","has-post-thumbnail","category-outros"],"image_feature":"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/COFRES.png","author_name":"gvb","_links":{"self":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/1102","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/comments?post=1102"}],"version-history":[{"count":3,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/1102\/revisions"}],"predecessor-version":[{"id":2276,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/1102\/revisions\/2276"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/media\/2428"}],"wp:attachment":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/media?parent=1102"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/categories?post=1102"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/tags?post=1102"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}