{"id":1083,"date":"2022-06-05T23:03:59","date_gmt":"2022-06-05T23:03:59","guid":{"rendered":"https:\/\/incendio.pt\/mse\/?p=1083"},"modified":"2026-02-21T19:02:17","modified_gmt":"2026-02-21T19:02:17","slug":"tipo-fechaduras","status":"publish","type":"post","link":"https:\/\/incendio.pt\/mse\/tipo-fechaduras\/","title":{"rendered":"Tipos de Fechaduras &#8211; SCAE"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\"><strong>Trinco El\u00e9ctrica<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fechadura eletromec\u00e2nica que substitui a fun\u00e7\u00e3o mec\u00e2nica do cilindro. O trinco \u00e9 recolhido mediante impulso el\u00e9trico, permitindo a abertura da porta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas t\u00e9cnicas comuns:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tens\u00e3o: 12V DC ou 24V DC<\/li>\n\n\n\n<li>Consumo: 0,3A a 0,8A (em funcionamento)<\/li>\n\n\n\n<li>Modo de funcionamento: Fail-secure (mant\u00e9m fechada sem energia)<\/li>\n\n\n\n<li>Norma aplic\u00e1vel: EN 14846 (Fechaduras electromec\u00e2nicas)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Aplica\u00e7\u00e3o:<\/strong> Portas interiores, escrit\u00f3rios, zonas de acesso restrito.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Testa El\u00e9ctrica<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dispositivo que substitui o batente da fechadura, permitindo a entrada do trinco mesmo quando a porta est\u00e1 trancada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas t\u00e9cnicas:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tens\u00e3o: 12V AC\/DC ou 24V AC\/DC<\/li>\n\n\n\n<li>Consumo: 0,2A a 1,5A<\/li>\n\n\n\n<li>Modo: Fail-secure (mant\u00e9m fechada sem energia) ou Fail-safe (mant\u00e9m aberta sem energia) <\/li>\n\n\n\n<li>Norma aplic\u00e1vel: EN 14846<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Aplica\u00e7\u00e3o:<\/strong> Portas de entrada principal, zonas com requisitos de sa\u00edda de emerg\u00eancia.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Electro\u00edman<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dispositivo que mant\u00e9m a porta fechada atrav\u00e9s de for\u00e7a magn\u00e9tica. Requer alimenta\u00e7\u00e3o cont\u00ednua para manter a porta trancada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas t\u00e9cnicas:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>For\u00e7a de reten\u00e7\u00e3o: 280 kg, 500 kg ou 1200 kg<\/li>\n\n\n\n<li>Tens\u00e3o: 12V DC ou 24V DC<\/li>\n\n\n\n<li>Consumo: 0,3A a 0,6A (permanente)<\/li>\n\n\n\n<li>Modo: Fail-safe (abre sem energia)<\/li>\n\n\n\n<li>Normas aplic\u00e1veis: EN 1155 (Sistemas de reten\u00e7\u00e3o electromagn\u00e9tica), EN 13637<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Legisla\u00e7\u00e3o:<\/strong> Regime Jur\u00eddico da Seguran\u00e7a Contra Inc\u00eandios em Edif\u00edcios (RJ-SCIE) &#8211; DL 220\/2008: exige modo fail-safe em portas de evacua\u00e7\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Motoriza\u00e7\u00e3o para Portas<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sistema motorizado que acciona o ferrolho atrav\u00e9s de motor el\u00e9trico.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas t\u00e9cnicas:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tens\u00e3o: 12V DC ou 24V DC<\/li>\n\n\n\n<li>For\u00e7a de bloqueio: at\u00e9 2000 N<\/li>\n\n\n\n<li>Modo: Fail-secure ou fail-safe (configur\u00e1vel)<\/li>\n\n\n\n<li>Norma aplic\u00e1vel: EN 14846<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Aplica\u00e7\u00e3o:<\/strong> Portas de alta seguran\u00e7a, cofres, salas t\u00e9cnicas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>5. Ventosa Electromagn\u00e9tica<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Variante do electro\u00edman aplicada directamente na folha da porta (n\u00e3o no caixilho).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas t\u00e9cnicas:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>For\u00e7a: 150 kg a 500 kg<\/li>\n\n\n\n<li>Instala\u00e7\u00e3o: Embutida ou \u00e0 superf\u00edcie<\/li>\n\n\n\n<li>Modo: Fail-safe<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Aplica\u00e7\u00e3o:<\/strong> Portas de vidro, portas corta-fogo com requisitos est\u00e9ticos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>6. Fechadura de Embutir Motorizada<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fechadura completa com cilindro europeu e motoriza\u00e7\u00e3o integrada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas t\u00e9cnicas:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Compat\u00edvel com cilindros DIN<\/li>\n\n\n\n<li>Certifica\u00e7\u00e3o: EN 12209 (Fechaduras mec\u00e2nicas)<\/li>\n\n\n\n<li>Interface: Impulso el\u00e9ctrico ou bus de comunica\u00e7\u00e3o<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Aplica\u00e7\u00e3o:<\/strong> Substitui\u00e7\u00e3o de fechaduras convencionais mantendo cilindro mec\u00e2nico como backup.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Trinco El\u00e9ctrica Fechadura eletromec\u00e2nica que substitui a fun\u00e7\u00e3o mec\u00e2nica do cilindro. O trinco \u00e9 recolhido mediante impulso el\u00e9trico, permitindo a abertura da porta. Caracter\u00edsticas t\u00e9cnicas comuns: Aplica\u00e7\u00e3o: Portas interiores, escrit\u00f3rios, zonas de acesso restrito. Testa El\u00e9ctrica Dispositivo que substitui o batente da fechadura, permitindo a entrada do trinco mesmo quando a porta est\u00e1 trancada. Caracter\u00edsticas [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2469,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[117,56],"tags":[],"class_list":["post-1083","post","type-post","status-publish","format-standard","has-post-thumbnail","category-scae-equipamentos","category-controlo-de-acessos-e-assiduidade"],"image_feature":"https:\/\/incendio.pt\/mse\/wp-content\/uploads\/scae-trincos.png","author_name":"gvb","_links":{"self":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/1083","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/comments?post=1083"}],"version-history":[{"count":4,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/1083\/revisions"}],"predecessor-version":[{"id":2180,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/posts\/1083\/revisions\/2180"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/media\/2469"}],"wp:attachment":[{"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/media?parent=1083"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/categories?post=1083"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incendio.pt\/mse\/wp-json\/wp\/v2\/tags?post=1083"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}