{"id":93,"date":"2020-07-31T14:20:31","date_gmt":"2020-07-31T14:20:31","guid":{"rendered":"https:\/\/incendio.pt\/manual-seguranca\/?p=93"},"modified":"2020-08-16T23:24:35","modified_gmt":"2020-08-16T23:24:35","slug":"sinalizacao-rt-scie-111o","status":"publish","type":"post","link":"https:\/\/incendio.pt\/manual-seguranca\/sinalizacao-rt-scie-111o\/","title":{"rendered":"SINALIZA\u00c7\u00c3O"},"content":{"rendered":"\n<h2>(RT-SCIE 111\u00ba)<\/h2>\n\n\n\n<p>Todos os edif\u00edcios devem possuir placas de sinaliza\u00e7\u00e3o de emerg\u00eancia adequada que indiquem respetivamente <strong>proibi\u00e7\u00e3o, perigo, emerg\u00eancia, meios de interven\u00e7\u00e3o<\/strong> <strong>e informa\u00e7\u00e3o<\/strong> consoante o seu formato e cor, devendo os mesmos serem em material r\u00edgido fotoluminescente.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-regular\"><table class=\"has-subtle-pale-green-background-color has-background\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><strong>TIPO<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>FORMATO<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>COR<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\">Exemplo<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Proibi\u00e7\u00e3o<\/td><td class=\"has-text-align-center\" data-align=\"center\">Circular<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vermelho<\/td><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" width=\"167\" height=\"237\" class=\"wp-image-766\" style=\"width: 80px;\" src=\"https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/07\/PR4110.png\" alt=\"\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Obriga\u00e7\u00e3o<\/td><td class=\"has-text-align-center\" data-align=\"center\">Circular<\/td><td class=\"has-text-align-center\" data-align=\"center\">Azul<\/td><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" width=\"336\" height=\"503\" class=\"wp-image-772\" style=\"width: 80px;\" src=\"https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/07\/capacete.jpg\" alt=\"\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Perigo<\/td><td class=\"has-text-align-center\" data-align=\"center\">Triangular<\/td><td class=\"has-text-align-center\" data-align=\"center\">Amarela<\/td><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" width=\"194\" height=\"263\" class=\"wp-image-771\" style=\"width: 80px;\" src=\"https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/07\/pe3253.png\" alt=\"\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Equipamento<\/td><td class=\"has-text-align-center\" data-align=\"center\">Retangular<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vermelho<\/td><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" width=\"100\" height=\"101\" class=\"wp-image-768\" style=\"width: 80px;\" src=\"https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/07\/IN9700.png\" alt=\"\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Emerg\u00eancia<\/td><td class=\"has-text-align-center\" data-align=\"center\">Retangular<\/td><td class=\"has-text-align-center\" data-align=\"center\">Verde<\/td><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" width=\"202\" height=\"100\" class=\"wp-image-769\" style=\"width: 80px;\" src=\"https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/07\/EM9746.png\" alt=\"\"><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Informa\u00e7\u00e3o<\/td><td class=\"has-text-align-center\" data-align=\"center\">Retangular<\/td><td class=\"has-text-align-center\" data-align=\"center\">Azul<\/td><td class=\"has-text-align-center\" data-align=\"center\"><img loading=\"lazy\" width=\"220\" height=\"222\" class=\"wp-image-770\" style=\"width: 80px;\" src=\"https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/07\/IS4500.png\" alt=\"\"><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Devem permitir a visibilidade a partir de qualquer ponto onde a informa\u00e7\u00e3o que cont\u00e9m deva ser conhecida e devem ser <strong>fixadas a uma altura entre 2,1 m e 3 m<\/strong>. (exceto informativas).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"945\" height=\"738\" src=\"https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/08\/sinalizacoes.jpg\" alt=\"\" class=\"wp-image-773\" srcset=\"https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/08\/sinalizacoes.jpg 945w, https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/08\/sinalizacoes-600x469.jpg 600w, https:\/\/incendio.pt\/manual-seguranca\/wp-content\/uploads\/2020\/08\/sinalizacoes-768x600.jpg 768w\" sizes=\"(max-width: 945px) 100vw, 945px\" \/><\/figure>\n\n\n\n<p>As placas devem ter um tamanho igual \u00e1 dist\u00e2ncia\u00b2\/2000, com dist\u00e2ncia m\u00ednima de 6 m e m\u00e1xima de 50 m, como mostram os exemplos do quadro seguinte:<\/p>\n\n\n\n<figure class=\"wp-block-table aligncenter\"><table class=\"has-subtle-pale-blue-background-color has-background\"><tbody><tr><td><strong>Dist\u00e2ncias de visualiza\u00e7\u00e3o<\/strong><\/td><td><strong>6 m <\/strong><\/td><td><strong>8 m<\/strong><\/td><td><strong>17 m<\/strong><\/td><td><strong>26 m<\/strong><\/td><td><strong>35 m<\/strong><\/td><\/tr><tr><td>\u00c1rea (cm2)<\/td><td>180<\/td><td>320<\/td><td>1445<\/td><td>3380<\/td><td>6125<\/td><\/tr><tr><td>Placa quadrada  (<strong>mm<\/strong>)<\/td><td>150x 150<\/td><td>200x 200<\/td><td>400x 400<\/td><td>600x<br>600<\/td><td>800x 800<\/td><\/tr><tr><td>Placa Retangular 1:2 (<strong>mm<\/strong>)<\/td><td>100x 200<\/td><td>150x 300<\/td><td>300x 600<\/td><td>500x  1000<\/td><td>600x <br>1200<\/td><\/tr><tr><td>Placa Retangular 2:3 (<strong>mm<\/strong>)<\/td><td>150x 200<\/td><td>200x 300<\/td><td>400x 600<\/td><td>500x <br>750<\/td><td>700x <br>1050<\/td><\/tr><\/tbody><\/table><figcaption>Exemplo de dist\u00e2ncias<\/figcaption><\/figure>\n\n\n\n<p>As placas de sinaliza\u00e7\u00e3o n\u00e3o devem ser colocadas sobre os aparelhos de ilumina\u00e7\u00e3o, mas pr\u00f3ximas dos mesmos (inferior a 2 m). (exceto se forem transparentes e os aparelhos forem permanentes)<\/p>\n\n\n\n<p>As placas de sinaliza\u00e7\u00e3o num edif\u00edcio devem, pelo menos, indicar:<\/p>\n\n\n\n<ul><li>Os Caminhos de evacua\u00e7\u00e3o, colocadas perpendicularmente ao sentido de fuga e nos locais de mudan\u00e7a de dire\u00e7\u00e3o, de maneira inconfund\u00edvel, a dist\u00e2ncias de 6 a 30 m<\/li><li>O n\u00ba do piso ou a sa\u00edda, consoante o caso<\/li><li>Meios de 1\u00aa e 2\u00aa interven\u00e7\u00e3o, preferencialmente na perpendicular ao eixo de vis\u00e3o. Quando os meios n\u00e3o estiverem vis\u00edveis, para al\u00e9m do sinal colocado na altura regulamentar, dever\u00e1 existir um outro sinal que identifique a localiza\u00e7\u00e3o do meio<\/li><li>Meios de alarme e alerta (bot\u00f5es de alarme, telefones de alerta, etc.)<\/li><li>Meios passivos e ativos, de comando ou opera\u00e7\u00e3o manual<\/li><\/ul>\n\n\n\n<p>As placas podem ter 3 tipos de fixa\u00e7\u00f5es:<\/p>\n\n\n\n<ul><li>Sinal de uma face (leitura de 90\u00ba em frente, paralela \u00e1 parede)<\/li><li>Sinal de dupla face (leitura de 90\u00ba em ambos os lados, perpendicular \u00e1 parede)<\/li><li>Sinal Panor\u00e2mico (leitura a 180\u00ba, em duas faces a 45\u00ba cada)<\/li><\/ul>\n\n\n\n<p>As placas t\u00eam tamb\u00e9m de ter a marca ou nome do fabricante e os valores de luminesc\u00eancia.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>(RT-SCIE 111\u00ba) Todos os edif\u00edcios devem possuir placas de sinaliza\u00e7\u00e3o de emerg\u00eancia adequada que indiquem respetivamente proibi\u00e7\u00e3o, perigo, emerg\u00eancia, meios de interven\u00e7\u00e3o e informa\u00e7\u00e3o consoante o seu formato e cor, devendo os mesmos serem em material r\u00edgido fotoluminescente. TIPO FORMATO COR Exemplo Proibi\u00e7\u00e3o Circular Vermelho Obriga\u00e7\u00e3o Circular Azul Perigo Triangular Amarela Equipamento Retangular Vermelho Emerg\u00eancia &hellip; <a href=\"https:\/\/incendio.pt\/manual-seguranca\/sinalizacao-rt-scie-111o\/\" class=\"more-link\">Continuar a ler<span class=\"screen-reader-text\">SINALIZA\u00c7\u00c3O<\/span> <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[116],"tags":[],"_links":{"self":[{"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/posts\/93"}],"collection":[{"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/comments?post=93"}],"version-history":[{"count":11,"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/posts\/93\/revisions"}],"predecessor-version":[{"id":774,"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/posts\/93\/revisions\/774"}],"wp:attachment":[{"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/media?parent=93"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/categories?post=93"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incendio.pt\/manual-seguranca\/wp-json\/wp\/v2\/tags?post=93"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}